TRIMBOX CLASS B+C SURGE ARRESTER
10 February 2025
Trimbox will be showcasing its products at Intersec Saudi Arabia 2025.
9 September 2025

TRIMBOX CLASS B SURGE ARRESTER

 

CLASS B SURGE ARRESTER

Class B surge arresters, which you can find under the old item number 718.560 and the new item number 35.115.2100 in the unit price list for panel type surge protectors or undervoltage arresters, are protection elements designed to be applied to the outermost parts of buildings.

Class B surge arresters are manufactured to absorb the first shock at the building entrance and prevent it from entering; It must withstand a lightning surge of 100kA at a voltage pulse of 2.5kV and have a discharge capacity of 50kA.

Since Class B surge arresters are used at building entrances, 4-pole versions are the most preferred, and their technical details are listed below.

2-Pole Class B Surge Arresters

Number of Poles: 2 (phase + neutral)

Operating Voltage V(in): 230V

Operating Frequency: 50/60 Hz

  • Voltage Protection Level Up <2.5kV
  • IEC Category Class I
  • Nominal voltage Un 230 V AC (230V AC – 275V AC)
  • Arestor nominal voltage Uc (L-N)275 V AC , Uc (L-PE)275 V AC
  • Nominal frequency Fn 50 Hz – 60 Hz
  • Maximum discharge current In 100kA ≤ 25ns
  • Nominal discharge current Iimp 50kA ≤ 25ns
  • Response Time (L-N) , (L-PE) ≤ 25ns
  • Input Connection Screw Terminal
  • Output Connection None
  • Screw Thread: M5, Torque: 4.5 Nm
        • Multi-core and Single-core conductor cross-section 2.5 mm2, 4 mm2
        • Standards/Regulations IEC 61643-11 2011, IEC 61643-11 2012
        • Protection class IP20
        • Housing material White ABS, UL’94 V-0 Flammability rating
        • Standards for spacing and dispersion distances DIN VDE 0110-1, IEC 60664-1
        • Overvoltage protection fault message: 1 LED
        • Direction of movement: L – N – PE
        • Mounting type: Design DIN rail 35mm, Rail module
        • Ambient temperature: -50 °C, +80 °C
        • Dimensions: 50 x 75 x 60mm

     

    4-Pole Class B Surge Arresters

      • Number of Poles 4 (3-phase + neutral)
      • Operating Voltage V(in) 230/400V
      • Operating Frequency 50/60 Hz
      • Voltage Protection Level Up <2.5kV
      • IEC Category Class I
      • Nominal voltage Un 230 V AC (230V AC – 275V AC)
      • Resector nominal voltage Uc (L-N)275 V AC , Uc (L-PE)275 V AC
      • Nominal frequency Fn 50 Hz – 60 Hz
      • Maximum discharge current In 100kA ≤ 25ns
      • Nominal discharge current Iimp 50kA ≤ 25ns
      • Response Time (L-N), (L-PE) ≤ 25ns
      • Input Connection: Screw Terminal
      • Output Connection: None
      • Screw Thread: M5, Torque: 4.5Nm
      • Multi-core and Single-core conductor cross-section: 2.5 mm2, 4 mm2
      • Standards/Regulations IEC 61643-11 2011, IEC 61643-11 2012
      • Protection class IP20
      • Housing material White ABS, UL’94 V-0 Fire resistance rating
      • Standards for clearance and dispersion distances DIN VDE 0110-1, IEC 60664-1